ceramic floor repair: Close-up of hands applying Boydur® M12 MMA mortar to a cracked ceramic tile floor, demonstrating targeted repair and surface integration.

Ceramic and tiled floor repair in factories, kitchens, car showrooms and service areas usually means rebuilding the concrete base where tiles have broken out and making the area safe to use again. Boydur® M12, an MMA repair mortar by Boytorun Kimya, fills and bonds to the prepared base and is traffic-ready in about one hour at 20°C.

Tiled floors · Floor repair

Ceramic and Tiled Floor Repair with MMA Mortar: Fix the Base, Reopen the Same Day

Boytorun Kimya Technical Team · Updated November 2026

Tiled floors in working areas rarely fail tile by tile. A forklift wheel, a dropped load or a hollow bedding layer breaks a group of tiles, the edges start to chip, and the hole grows with every pass. Re-tiling with cement-based adhesive and grout means keeping the area closed until everything has hardened.

≈60 minTraffic-ready at 20°C
−10°CLowest application temperature
≥5 mmMinimum thickness
≈34 N/mm²Typical compressive strength

When MMA mortar is the right repair for a tiled floor

  • Broken-out areas in technical and back-of-house floors — the hole is cut back and filled flush with M12 so traffic can return within about one hour.
  • Rebuilding the base before re-tiling — damaged screed or concrete under the tiles is repaired quickly, so new tiles can be laid without waiting days.
  • Edges, thresholds and drainage channels — chipped tile edges next to channels, doors and ramps are rebuilt to stop further breakage.
  • Cold rooms and outdoor tiled areas — application is possible down to −10°C, with longer curing in the cold.

Good to know: M12 bonds to sound, dry, prepared concrete and mineral substrates. Glazed tile surfaces are smooth and must be mechanically roughened and primed if the mortar is to bond to them. Loose or hollow tiles are always removed first. The standard colour is concrete grey, so M12 is not a decorative match for finished tiles.

How the repair is done

  1. Remove broken and hollow-sounding tiles around the damage until you reach firmly bonded tiles.
  2. Cut back weak bedding and concrete, clean, and make sure the base is completely dry.
  3. Prime the absorbent mineral base and let the primer cure.
  4. Mix Boydur® M12 and place it within ≈25 minutes at 20°C, at least 5 mm thick, compacted and levelled to the surrounding tiles.
  5. Reopen to traffic after about one hour at 20°C, or lay new tiles on the repaired base.

Typical places

Food and beverage production floors, commercial kitchens, car showrooms and workshops, cold stores, hospital service corridors and loading areas — anywhere tiles take wheeled traffic and the area cannot stay closed for long.

Frequently asked questions

Can Boydur® M12 be applied directly onto ceramic tiles?

Only after the glazed surface has been mechanically roughened and primed, and the tiles are firmly bonded. Confirm the build-up with our technical team.

How quickly can the area be used?

At 20°C the repaired area is typically traffic-ready in about one hour. Lower temperatures extend curing.

Can I re-tile on top of the repair?

Yes. Rebuilding the base with M12 is a quick way to prepare for re-tiling. Follow the tile adhesive manufacturer's instructions for bonding to the cured repair.

Will the repair match the tile colour?

No. The standard colour is concrete grey. For visible decorative areas, use M12 to rebuild the base and lay new tiles on top.

Values are typical. The current Technical Data Sheet and Safety Data Sheet take precedence. Suitability for each project should be confirmed with the Boytorun technical team.

Broken tiles in a working area?

Send photos and dimensions — we will tell you whether to fill flush with M12 or rebuild the base for new tiles.